Jul 24, 2025
In modern society, electricity has become an indispensable core element in daily life and industrial production. However, sudden power outages may lead to catastrophic consequences, especially in emergency situations such as natural disasters, extreme weather or power grid failures. At this time, how to quickly restore power supply and ensure the stable operation of infrastructure has become the most critical task. In this context, diesel generator sets, as a flexible, efficient and reliable emergency power solution, are widely used in various fields, providing strong guarantees for the normal operation of society.
Diesel generator sets consist of diesel engines and generators. The working principle is simple and efficient: the engine is driven by diesel combustion, which is converted into mechanical energy, and then converted into electrical energy for various loads. Its advantages are rapid startup, stable operation, and strong adaptability. Compared with other power generation methods, diesel generator sets have shown unique advantages in emergency power supply:
1. Rapid startup: One of the biggest features of diesel generator sets is its extremely fast startup speed. Usually, it only takes a few seconds from startup to power generation. This makes diesel generator sets the preferred equipment in emergency scenarios, especially in emergency situations such as natural disasters, where power supply can be quickly restored.
2. Efficient and reliable: Diesel generator sets have high fuel efficiency and can maintain low operating costs even when running at full load. Compared with other power generation equipment, it shows higher reliability and stability when working continuously, and can ensure long-term uninterrupted power output.
3. Strong adaptability: Diesel generator sets can operate in various complex environments, including extreme temperature, humidity, wind and other environmental conditions. This makes it suitable not only for emergency power supply in cities, but also for remote areas, mountainous areas and temporary construction sites.
4. Easy maintenance: Diesel generator sets are relatively simple to maintain and maintain, and many devices are equipped with automatic monitoring systems that can promptly remind users to perform maintenance or detect potential faults, reducing the risk of unexpected downtime.
Model | Prime Power(KVA) |
FD-YC40 | 40 |
FD-YC50 | 50 |
FD-YC55 | 55 |
FD-YC60 | 60 |
FD-YC75 | 75 |
FD-YC88 | 88 |
FD-YC100 | 100 |
FD-YC110 | 110 |
FD-YC130 | 130 |
FD-YC150 | 150 |
FD-YC170 | 170 |
FD-YC175 | 175 |
FD-YC180 | 180 |
FD-YC200 | 200 |
FD-YC225 | 225 |
FD-YC250 | 250 |
FD-YC300 | 300 |
FD-YC350 | 350 |
FD-YC375 | 375 |
FD-YC400 | 400 |
FD-YC450 | 450 |
FD-YC485 | 485 |
FD-YC500 | 500 |
FD-YC560 | 560 |
FD-YC575 | 575 |
FD-YC600 | 600 |
FD-YC625 | 625 |
FD-YC685 | 685 |
FD-YC750 | 750 |
FD-YC800 | 800 |
FD-YC875 | 875 |
FD-YC900 | 900 |
FD-YC960 | 960 |
FD-YC1000 | 1000 |
FD-YC1100 | 1100 |
FD-YC1200 | 1200 |
FD-YC1250 | 1250 |
FD-YC1360 | 1360 |
FD-YC1400 | 1400 |
FD-YC1500 | 1500 |
FD-YC1600 | 1600 |
FD-YC1850 | 1850 |
FD-YC1900 | 1900 |
FD-YC2200 | 2200 |
FD-YC2400 | 2400 |
FD-YC2650 | 2650 |
FD-YC2900 | 2900 |
FD-YC3000 | 3000 |
FD-YC3300 | 3300 |
FD-YC3600 | 3600 |
Model | Rated power/speed (KW/rpm) |
Maximum power/speed (KW/rpm) |
YC4D60-D21 | 40/1500 | 44/1500 |
YC4D65-D20 | 44/1800 | 48/1800 |
YC4D80-D34 | 53/1500 | 59/1500 |
YC4D90-D34 | 60/1500 | 66/1500 |
YC4D105-D34 | 70/1500 | 77/1500 |
YC4D120-D31 | 80/1500 | 88/1500 |
YC4D140-D31 | 100/1500 | 110/1500 |
YC4A140L-D25 | 100/1500 | 110/1500 |
YC4D180-D33 | 120/1800 | 132/1800 |
YCD6Q23H8-210 | 140/1500 | 154/1500 |
YC6A230L-D20 | 155/1500 | 170.5/1500 |
YC6A230-D30 | 155/1500 | 171/1500 |
YC6A245L-D21 | 165/1500 | 181/1500 |
YCD6Q33H6-260 | 190/1500 | 209/1500 |
YC6A305-D32 | 203/1800 | 223/1800 |
YC6MK360L-D20 | 235/1500 | 251/1500 |
YC6MK420L-D20 | 281/1500 | 309/1500 |
YC6MK450-D30 | 301/1500 | 331/1500 |
YC6MJ500-D30 | 334/1500 | 367/1500 |
YC6MJ540-D30 | 365/1500 | 402/1500 |
YC6MJ600-D30 | 401/1500 | 441/1500 |
YC6T660L-D20 | 441/1500 | 485/1500 |
YC6K660-D30 | 441/1500 | 490/1500 |
YC6TD780-D31 | 520/1500 | 572/1500 |
YC6TD780-D31 | 520/1500 | 572/1500 |
YC6TC840-D31 | 561/1500 | 616/1500 |
YC6TD840-D31 | 561/1500 | 616/1500 |
YC6TD900-D31 | 605/1500 | 665/1500 |
YC6TD1000-D30 | 668/1500 | 735/1500 |
YC6TH1070-D31 | 715/1500 | 787/1500 |
YCDV270A3H-1200 | 800/1500 | 880/1500 |
YC6TH1220-D31 | 815/1500 | 897/1500 |
YCDV270A3H-1320 | 880/1500 | 968/1500 |
YCDV270A3H-1320 | 880/1500 | 968/1500 |
YC12VTD1500-D31 | 1000/1500 | 1100/1500 |
YC6C1660-D31 | 1110/1500 | 1221/1500 |
YC6C1660-D31 | 1110/1500 | 1221/1500 |
YC12VTD1860-D33 | 1240/1800 | 1364/1800 |
YC12VTD2000-D30 | 1345/1500 | 1480/1500 |
YC12VC2070-D31 | 1380/1500 | 1520/1500 |
YC12VC2170-D33 | 1450/1200 | 1595/1200 |
YC12VC2510-D31 | 1680/1500 | 1850/1500 |
YC12VC2700-D31 | 1805/1500 | 1985/1500 |
YC12VC3000-D30 | 2005/1500 | 2206/1500 |
YC16VC3300-D31 | 2205/1500 | 2426/1500 |
YC16VC3600-D31 | 2405/1500 | 2646/1500 |
YC16VC4000-D31 | 2673/1500 | 2940/1500 |
YC16VC4200-D30 | 2808/1500 | 3089/1500 |
YC16VC4500-D30 | 3010/1500 | 3311/1500 |
YC16VC4900-D30 | 3280/1500 | 3608/1500 |
Natural disasters such as earthquakes, typhoons, and floods usually have a devastating impact on power infrastructure. At this time, diesel generator sets can be put into use quickly as emergency power sources to restore power supply. The rapid startup characteristics of diesel generator sets make them key equipment for restoring power supply after disasters.
For example, after sudden earthquakes or floods, power facilities are often damaged to varying degrees, resulting in large-scale power outages. Diesel generator sets can start up in seconds and provide power guarantee for post-disaster rescue command centers, temporary settlements, and residential areas. In the rescue process, the role of generator sets is crucial. It not only provides power support for communication equipment and medical facilities, but also provides basic lighting and daily necessities for residents in disaster areas.
In many emergency situations, the power supply of critical infrastructure such as hospitals is crucial, and any power outage will have serious consequences. For example, in operating rooms, intensive care units and other medical facilities, life support systems, ventilators and other equipment need to be powered on continuously to ensure patient safety. In this case, diesel generator sets provide hospitals with the necessary power guarantee.
Whether it is a large city hospital or a clinic in a remote area, diesel generator sets are usually used as backup power systems, which are immediately activated when the mains power supply is interrupted to ensure that key equipment such as medical monitoring instruments and surgical lights can continue to operate.
In the information age, the power supply of data centers and communication facilities is extremely important. Data loss, network interruption or communication failure may cause huge social and economic losses. In order to ensure the stability of data and communication, many data centers and communication base stations use diesel generator sets as emergency backup power supplies to ensure 24-hour uninterrupted power supply.
For example, when there is a problem with the power grid or a power outage occurs, the diesel generator sets will start quickly and take over the power supply to avoid data loss or business interruption caused by power outages. Many leading global Internet companies, such as Google and Amazon, deploy diesel generator sets in their data centers to ensure the continued stability of global services.
In construction sites and industrial production lines, power outages may cause project delays, equipment damage, and even safety hazards. Especially in remote areas, where there is less reliance on municipal power grids, diesel generator sets are usually the main source of electricity. In this case, diesel generator sets can provide stable power for construction equipment, welding machines, lighting, etc., ensuring the normal operation of the construction site.
In many large-scale construction projects, diesel generator sets are often used in combination with other backup power systems as an important guarantee for the smooth progress of the project. For example, equipment such as cranes and concrete mixers on construction sites require a stable power supply, and the power provided by diesel generator sets is not only stable and reliable, but also effectively avoids the impact of municipal power instability on the project.
Even in daily operations, fluctuations in the power grid may cause damage to industrial equipment, precision instruments and production lines. As a backup power source, diesel generator sets can switch power supply in time when abnormal fluctuations occur in the power grid to ensure the normal operation of equipment and production lines. Especially in those industries with extremely high requirements for power supply, such as semiconductor manufacturing, power electronics, etc., the emergency role of diesel generator sets is particularly important.
In this application scenario, diesel generator sets are not only emergency power sources for power outages, but can also prevent damage to equipment caused by voltage fluctuations, ensuring that the company's production and operations are not affected.